Reproducibility of liver stiffness measurements made with two different 2-dimensional shear wave elastography systems using the comb-push technique
Hwaseong Ryu, Su Joa Ahn, Jeong Hee Yoon, Jeong Min Lee
Ultrasonography. 2019;38(3):246-254.   Published online 2018 Nov 23     DOI: https://doi.org/10.14366/usg.18046
Citations to this article as recorded by Crossref logo
Accuracy and concordance of two-dimensional shear-wave elastography using transient elastography as the reference in chronic viral hepatitis and HIV infection in Rio de Janeiro, Brazil
Mariana Coelho, Flavia Fernandes, Sandra W. Cardoso, Juliana Piedade, Marcos Vinícius Torres da Silva, Ricardo Santos, Valdilea G. Veloso, Beatriz Grinsztejn, Gustavo Henrique Pereira, Hugo Perazzo
European Journal of Gastroenterology & Hepatology.2023; 35(5): 583.     CrossRef
The Relationship of Liver Stiffness with Liver Size, Age, Gender, and Body Mass Index in Child and Adult Age Groups by 2-D Shear Wave Elastography
Eda ALBAYRAK, Ergün SÖNMEZGÖZ, Meral Gizem AKBAŞ, Osman DEMİR
Düzce Tıp Fakültesi Dergisi.2022; 24(2): 157.     CrossRef
Interobserver and Intraobserver Reliability of Hepatic Shear Wave Elastography and the Influence of Fasted Versus Nonfasted States in Healthy Volunteers
Zerlene Lim, Toni Whitaker, Kandis DeColle, Katie Barrett, Cayla Harlton, Lee Paskar, Gavin Low
Journal of Ultrasound in Medicine.2021; 40(2): 259.     CrossRef
Reproducibility of shear wave elastography among operators, machines, and probes in an elasticity phantom
Abdulaziz Ibrahim Alrashed, Abdulrahman M. Alfuraih
Ultrasonography.2021; 40(1): 158.     CrossRef
Ultrasound-guided transient elastography and two-dimensional shear wave elastography for assessment of liver fibrosis: emphasis on technical success and reliable measurements
Jihyuk Lee, Hyo-Jin Kang, Jeong Hee Yoon, Jeong Min Lee
Ultrasonography.2021; 40(2): 217.     CrossRef
Refraction artifact on abdominal sonogram
Hiroko Naganuma, Hideaki Ishida, Atsushi Uno, Hiroshi Nagai, Masahiro Ogawa, Naohisa Kamiyama
Journal of Medical Ultrasonics.2021; 48(3): 273.     CrossRef
Liver stiffness measured with two-dimensional shear wave elastography comparable to histopathology falls dominantly on the severe liver fibrosis
Ya Li, Size Wu
Clinical Hemorheology and Microcirculation.2021; 79(4): 587.     CrossRef
The Diagnostic Accuracy of LOGIQ S8 and E9 Shear Wave Elastography for Staging Hepatic Fibrosis, in Comparison with Transient Elastography
Jeong-Ju Yoo, Sang Gyune Kim, Young Seok Kim
Diagnostics.2021; 11(10): 1817.     CrossRef
2D shear wave elastography (SWE) performance versus vibration-controlled transient elastography (VCTE/fibroscan) in the assessment of liver stiffness in chronic hepatitis
Ahmed M. Osman, Ahmed El Shimy, Mohamed M. Abd El Aziz
Insights into Imaging.2020;[Epub]     CrossRef
Comparison of point and 2-dimensional shear wave elastography for the evaluation of liver fibrosis
Sang Min Lee, Min-Jeong Kim, Jeong Hee Yoon, Wonju Hong, Hong Il Ha, Kwanseop Lee, Ji-Young Choe, Jung Woo Lee, Sam-Youl Yoon, Junhee Han
Ultrasonography.2020; 39(3): 288.     CrossRef
Diagnostic problems in two-dimensional shear wave elastography of the liver
Hiroko Naganuma, Hideaki Ishida, Atsushi Uno, Hiroshi Nagai, Hidekatsu Kuroda, Masahiro Ogawa
World Journal of Radiology.2020; 12(5): 76.     CrossRef
Added value of 2D shear wave imaging of the gallbladder bed of the liver for acute cholecystitis
Ara Ko, Eun Sun Lee, Hyun Jeong Park, Sung Bin Park, Hee Sung Kim, Byung Ihn Choi
Ultrasonography.2020; 39(4): 384.     CrossRef
Prospective comparison of 2D-shearwave elastography in both liver lobes in healthy subjects and in patients with chronic liver disease
Golo Petzold, Bastian Grieme, Sebastian C. B. Bremer, Richard F. Knoop, Robert G. Goetze, Volker Ellenrieder, Steffen Kunsch, Albrecht Neesse
Scandinavian Journal of Gastroenterology.2019; 54(9): 1138.     CrossRef