Jung, Kim, Moon, Yoon, and Kim: Ultrasonography-guided 14-gauge core biopsy of the breast: results of 7 years of experience

Abstract

Purpose

This study assessed the outcomes of ultrasound (US)-guided core needle biopsies (CNBs) of breast lesions with at least 2 years of follow-up to determine the false-negative rate and to evaluate the diagnostic accuracy of CNB.

Methods

We retrospectively analyzed 13,254 consecutive US-guided 14-gauge CNBs for breast lesions. We excluded biopsies if non-malignant biopsy result was not confirmed by surgical excision or US-guided vacuum-assisted biopsy, or fewer than 2 years of follow-up data were available. A total of 4,186 biopsies were excluded, and 9,068 breast masses from 7,039 women were included. The pathologic findings from each CNB were assessed using the standard diagnostic reference, defined based on the results of surgical excision, vacuum-assisted biopsy, or at least 2 years of long-term imaging follow-up. The false-negative rate and underestimation rate were calculated.

Results

Of the 9,068 CNBs, benign pathology was found in 64.2%, high-risk results in 3.5%, and malignant results in 32.3%. Of the 5,821 benign CNBs, an additional malignancy was found at excision in 63 lesions, leading to a false-negative rate of 2.0% (63 of 3,067). The underestimation rate was 33.6% (111 of 330) for ductal carcinoma in situ and 24.5% (79 of 322) for high-risk results at surgical excision. Most false-negative diagnoses (84.1%, 53 of 63) were recognized through imaging-histology correlations, and immediate rebiopsies were performed. Ten malignancies (15.9%, 10 of 63) had delayed diagnoses and showed progression in follow-up US imaging.

Conclusion

US-guided 14-gauge CNB provided optimal diagnostic information. Imaging-histology correlations and appropriate imaging follow-up should be performed to avoid delayed diagnoses.

Introduction

Imaging-guided core needle biopsy (CNB) is becoming the standard of diagnosis for breast disease as a reliable alternative to open excision biopsy [1-5]. Percutaneous image-guided CNB is performed under either stereotactic or ultrasonographic guidance. Percutaneous ultrasound (US)-guided breast biopsy has several advantages over stereotactic or surgical biopsy, and many studies have reported CNB to be effective and safe. This procedure is safe; faster; less expensive; is performed in real time, allowing accurate assessments; and does not involve ionizing radiation [4,6,7].
However, the possibility of false-negative results is unavoidable; false-negatives can result from core needle sampling errors, failure to recognize imaging-histology discordances, and inappropriate follow-up periods for benign biopsies [8,9]. A delayed diagnosis of breast cancer is an outcome that every clinician strives to avoid. In previous studies of US-guided 14-gauge CNBs with at least 2 years of follow-up, the false-negative rates has ranged from 0.1% to 2.5% [5,10-12]. So far, some studies have been published on US-guided CNB for breast lesions with long-term follow-up periods [5,6,13,14], but most previous reports of US-guided CNB in the breast were based on a small number of biopsies. Furthermore, few studies have reported large series of US-guided CNB with long-term follow-up; therefore, this study was undertaken, based on a relatively large series of US-guided 14-gauge CNB procedures performed for breast lesions with long-term follow-up periods.
The purpose of this study was to assess the outcomes of US-guided CNB for breast lesions that had at least a 2-year follow-up for benign lesions in a large series to determine the false-negative rate and to evaluate the diagnostic performance of CNB.

Materials and Methods

Study Population

This study was conducted with Institutional Review Board approval, and informed consent was waived because of the retrospective nature of this study.
From July 2005 to December 2012, 13,254 consecutive US-guided 14-gauge CNBs for breast lesions were performed at our institution. We retrospectively reviewed all the biopsy results and excluded 4,186 biopsies for which a non-malignant biopsy result was not confirmed by surgical excision or US-guided vacuum-assisted biopsy, or at least 2 years of follow-up data were not available.
A total of 9,068 breast masses in 7,039 women (age range, 11 to 92 years; mean, 46 years) were included in this study. Of the 7,039 patients, 1,253 had biopsies of two separate lesions, 234 had biopsies of three separate lesions, 74 had biopsies of four separate lesions, 11 had biopsies of five separate lesions, four had biopsies of six separate lesions, one had biopsies of seven separate lesions, one had biopsies of eight separate lesions, and one had biopsies of 10 separate lesions.

Biopsy Procedure

US-guided 14-gauge CNB was performed using a free-hand technique and a high-resolution US unit with 7.5- or 12-MHz linear array transducers (HDI 5000 or IU22, Philips-Advanced Technology Laboratories, Bothell, WA, USA; or Logiq 9, GE Healthcare, Milwaukee, WI, USA). Each procedure was performed in an outpatient setting under local anesthesia with the patient in the supine position. A 14-gauge automated core biopsy needle with a spring-loaded biopsy gun (Promac 2.2L, Manan Medical Products, Northbrook, IL, USA) or a 14-gauge dual-action semiautomatic core biopsy needle with a 22-mm throw (Stericut cut with coaxial, TSK Laboratory, Tochigi, Japan) was used. All biopsies were performed by one of 19 radiologists in fellowship training (n=15) or with extensive clinical experience (n=4) who were specialists in breast imaging and biopsies. According to our standard protocol, four or five core samples per lesion were routinely obtained.

Post-biopsy Procedure

For each lesion that underwent a CNB, a radiologist reviewed the pathology report in conjunction with the images obtained before, during, and after the biopsy procedure, and based on the results of the review, an addendum was attached to the biopsy report recommending specific management strategies for the patients and the referring physicians [15,16]. The imaging and histological findings were considered to be concordant when the histological findings provided a sufficient explanation for the imaging findings and discordant when they did not [15]. For malignant lesions (e.g., invasive carcinoma, ductal carcinoma in situ [DCIS], and metastases) identified through 14-gauge CNB, immediate definitive surgery or chemotherapy was recommended, in accordance with what was deemed clinically appropriate. For high-risk lesions (e.g., atypia including atypical ductal hyperplasia [ADH], lobular neoplasia, radial sclerosing lesions, and possible phyllodes tumors) and benign lesions (neither malignant nor high-risk) with imaging-histology discordance (i.e., a lesion that was thought to be malignant based on imaging but was demonstrated to be benign by histological findings) resulted in recommendations for surgical excision [15,17].
US follow-up at 6 months after biopsy and then annually for at least 2 years was recommended in patients with concordant benign lesions (i.e., a lesion that was suspected of being benign based on imaging and also proven to be benign by the histological findings). For some concordant benign lesions, rebiopsies were carried out by surgical excision or US-guided vacuum-assisted biopsy at the request by the patient or referring physician or because of suspicious physical findings (i.e., a palpable mass or nipple discharge) or lesion progression at US follow-up. The choice of surgical excision or US-guided vacuum-assisted biopsy at rebiopsy depended on the patient’s or referring physician’s preferences.

Data Analysis

The pathologic findings of US-guided 14-gauge CNBs and rebiopsies, as well as the follow-up results, were obtained from patients’ medical records. After reviewing the results, pathologic comparisons between US-guided 14-gauge CNB results and the standard diagnostic reference were made. The standard diagnostic reference included the results of surgical excision, vacuum-assisted biopsy, or at least 2 years of long-term imaging follow-up. The false-negative rate was calculated as the proportion of benign results from US-guided 14-gauge CNBs among all breast cancers [5,10]. The underestimation rate for high-risk lesions was calculated as the proportion of lesions diagnosed as high-risk by CNB that were finally proven to be DCIS or invasive cancer after surgical excision. The underestimation rate for DCIS was likewise defined as the proportion of lesions diagnosed as DCIS by CNB that were finally proven to be invasive cancer after surgical excision [5]. For the false-negative results of US-guided 14-gauge CNB, the time interval between the CNB and rebiopsy, as well as the reasons for rebiopsy, were reviewed.

Results

The lesions ranged in size from 2 to 130 mm (mean, 14.0 mm) as measured by US. The distribution of size and Breast Imaging-Reporting and Data System (BI-RADS) categories are summarized in Table 1. Of 9,068 breast masses, 4,408 lesions (48.6%) were less than 10 mm, and the most common indication for biopsy was the presence of a BI-RADS category 4a lesion (54.0%, 4,900 of 9,068). Three CNBs were BI-RADS category 1; among these, two cases were regarded as normal breast tissue on US, but the patient requested a biopsy. The remaining such case was a patient who had undergone a mastectomy and showed normal breast tissue on US, but a positron emission tomography scan revealed increased fluorodeoxyglucose uptake. All three cases were identified as benign on pathologic reports after the biopsies.

Pathologic Results and Underestimation Rate of CNB

Among the 9,068 breast masses, the pathologic results of US-guided 14-gauge CNB were benign in 64.2% (5,821 lesions), high-risk in 3.5% (322 lesions), and malignant in 32.3% (330 DCIS lesions and 2,595 cases of invasive cancer) (Tables 2, 3). A total of 4,782 cases were confirmed by surgical excision or US-guided vacuum-assisted biopsy; in these cases, breast cancer was found in 3.2% (63 of 1,990) of benign CNBs, 26.3% (79 of 300) of high-risk CNBs, and 100% (2,492 of 2,492) in malignant CNBs at the final diagnosis. The malignancy rates were 0% (0 of 3) for lesions in BI-RADS category 1, 2.8% (1 of 35) in category 2, 2.2% (28 of 1,248) in category 3, 9.4% (463 of 4,900) in category 4a, 47.7% (267 of 560) in category 4b, 83.9% (640 of 762) in category 4c, and 97.8% (1,526 of 1,560) in category 5. The underestimation rate was 33.6% (111 of 330) for DCIS and 24.5% (79 of 322) for high-risk lesions at surgical excision (Fig. 1).

False-Negative Results

Of the 5,821 benign CNB results, 63 lesions were confirmed to be malignant after surgical excision (1.1%, 63 of 5,821). After postbiopsy review, 5,586 benign CNBs showed imaging-pathology concordance, which included 29 lesions that were ultimately diagnosed as malignant (0.5%, 29 of 5,586), while 235 benign CNBs showed imaging-pathology discordance (Fig. 2), including 34 lesions determined to be malignant after the subsequent surgical excision (14.4%, 34 of 235). A total of 3,067 cases were malignant at the final diagnosis, and the false-negative rate was 2.0% (63 of 3,067) with a sensitivity of 95.4% (2,927 of 3,067). Of the false-negative results, papillary lesions represented the highest percentage (36.5%, 23 of 63), followed by fibrocystic changes (20.6%, 13 of 63) and fibrosis (9.5%, 6 of 63) (Table 2). Most false-negative diagnoses (84.1%, 53 of 63) underwent immediate rebiopsy (interval range, 3 to 79 days; mean, 31.1 days) because the radiologist noted the discordance between the imaging findings and CNB and recommended surgical excision or a vacuum-assisted biopsy.

Analysis of Delayed False-Negative Diagnoses

Ten malignancies (15.9%, 10 of 63) had delayed diagnoses, and the mean time interval between the initial CNB and excision was 11.6 months (range, 5 to 17 months) (Table 4). For five benign lesions, although radiologists performed imaging-pathology correlations and recommended surgical excision immediately after the initial CNB, the patients refused excision, resulting in delayed diagnoses of malignancy. All 10 delayed false-negative diagnoses showed progression in follow-up US imaging (Fig. 3). Of the five cases in which excision was refused, one lesion (Table 4, patient 1) was categorized as BI-RADS category 4a and the result of the initial US-guided CNB was fibrocystic change, which was considered to be concordant. However, a radiologist recommended surgical excision because of its large size (30 mm); the lesion increased in size from 30 to 43 mm over 17 months, and was confirmed as a malignant phyllodes tumor following surgical excision. Another patient (Table 4, patient 8) had a history of breast surgery due to intraductal papilloma 13 years ago, and a new mass was categorized as BI-RADS category 4a. The result of CNB was focal fibrosis, but a radiologist concluded that the lesion had high possibility of being intraductal papilloma and recommended surgical excision. The lesion markedly increased in size from 24 to 50 mm over 17 months, and was confirmed as invasive lobular carcinoma following surgical excision. Both of these patients refused excision after the initial CNB, causing delayed diagnoses of malignancy.

Discussion

In this study, we analyzed a large population in which US-guided CNBs of breast lesions were performed from July 2005 to December 2012, building upon the previous study conducted from February 2000 through June 2005 at our institution [5]. The inclusion criteria were the same in both studies, and we included a total of 9,068 breast masses in this study, in contrast to 2,420 masses in the previous study. The mean lesion size was smaller in this study (mean, 14.0 mm; range, 2 to 130 mm) than in the previous study (mean, 18.7 mm; range, 2 to 180 mm), but we showed a lower false negative rate of 2.0% (63 of 3,067) than the false-negative rate of 2.4% (31 of 1,312) observed in the previous study. Overall, the results of our study showed that US-guided 14-gauge CNB for breast lesions exhibited better performance, based on the analysis of a larger population with smaller lesions in contrast to the sample of the preceding study from the same institution.
False-negative diagnoses are unavoidable for reasons such as sampling errors, failure to act upon imaging-histology discordances, or the absence of imaging follow-up after a benign biopsy [9]. However, most false-negative diagnoses can be immediately recognized through careful post-biopsy review, as was exemplified by our data. Most of our false-negative results (84.1%, 53 of 63) underwent immediate rebiopsies, avoiding delayed diagnoses of cancer, because imaging-pathology discordances were promptly detected by radiologists. Previous studies have shown similar results [5,6,13,18]. Several studies have suggested that physicians should perform rebiopsies or surgical excision for discordant CNBs because of the high prevalence of carcinoma in imaging-pathology discordant lesions [15,19,20]. Our data likewise showed a much higher malignant rate of 14.4% in discordant benign CNBs, which is within the 6.8%-24.4% range reported in previous studies [15,19,21], compared with a malignancy rate of 0.5% in concordant benign CNBs. These results accentuate the importance of imaging-pathology correlations after biopsy and the significance of discordant lesions.
Of the false-negative diagnoses, papillary lesions comprised the largest subgroup (36.5%, 23 of 63) in terms of the histological classification, and 3.1% (23 of 728) of the papillary lesions that underwent CNB were upgraded to malignancy; this is comparable with previous studies, in which 2.3%-14% of papillary lesions were upgraded to DCIS or invasive cancer after surgical excision [22-26]. To decide whether a papillary lesion is benign or malignant on the basis of CNB is challenging because of the heterogeneity of papillomas and targeting error [27,28]. It remains controversial whether all benign papillary lesions on CNB should undergo surgical excision to avoid false-negative diagnoses. Our data showed an upgrade rate to carcinoma of only 2.3% (16 of 686) in concordant papillomas, in contrast to an upgrade rate of 16.6% (7 of 42) in discordant papillomas; this supports the suggestions of recent reports that observation is sufficient, rather than surgical excision, for papillomas identified as benign by CNB if the imaging-pathology findings are concordant [26,29].
Ten malignancies had delayed diagnoses without immediate rebiopsies in the false-negative results. All these lesions showed progression in follow-up US. After review of the patients’ medical records, we found that patients refused excision for five false-negative lesions, although radiologists performed imaging-pathology correlations for these lesions and recommended surgical excision immediately after the initial CNB. The other five delayed false-negative diagnoses were identified as malignancies on follow-up sonography within 1 year after the initial CNB. Our results suggest that it is important to consider not only appropriate follow-up, but patient compliance after the biopsy. In previous studies, compliance rates of only 54% (49 of 90 lesions) [30] and 50.9% (84 of 165 lesions) [31] were reported for imaging surveillance recommendations. Therefore, poor patient compliance and inappropriate follow-up may cause further delays in the diagnosis and treatment of breast cancer, even if imaging-pathology discordances are recognized immediately.
One of the limitations of CNB is the histologic underestimation of breast malignancy, which means that lesions found to be high-risk or DCIS by a percutaneous breast biopsy are upgraded to DCIS or invasive cancer after surgical excision. In previous studies, the underestimation rates ranged from 6.25% to 65% for ADH and from 16% to 66% for DCIS using CNB or vacuum-assisted biopsy [13,32-35]. Our underestimation rates were 24.5% for high-risk lesions (79 of 322) and 33.6% for DCIS (111 of 330), comparable with previous reports.
Our study has a few limitations. First, there was no retrospective pathologic review of the core needle samples for the false-negative results. Second, the radiologists who performed the biopsies were heterogeneous, and included radiologists undergoing fellowship training (n=15). However, our institution is a tertiary hospital and it is natural for less experienced trainees to perform biopsies. Furthermore, our results showed reliable sensitivity (95.4%) and a low false-negative rate (2.0%).
In conclusion, US-guided 14-gauge CNB is accurate and provides optimal diagnostic information for breast lesions. Imaging-histology correlations and appropriate imaging follow-up should be performed to identify possible false-negative results and to avoid delayed diagnoses.

Conflict of Interest

No potential conflict of interest relevant to this article was reported.

References

1. Fuhrman GM, Cederbom GJ, Bolton JS, King TA, Duncan JL, Champaign JL, et al. Image-guided core-needle breast biopsy is an accurate technique to evaluate patients with nonpalpable imaging abnormalities. Ann Surg 1998;227:932–939.
crossref pmid pmc
2. Liberman L. Clinical management issues in percutaneous core breast biopsy. Radiol Clin North Am 2000;38:791–807.
crossref pmid
3. Dillon MF, Hill AD, Quinn CM, O'Doherty A, McDermott EW, O'Higgins N. The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases. Ann Surg 2005;242:701–707.
crossref pmid pmc
4. Bassett LW, Mahoney MC, Apple SK. Interventional breast imaging: current procedures and assessing for concordance with pathology. Radiol Clin North Am 2007;45:881–894.
crossref pmid
5. Youk JH, Kim EK, Kim MJ, Oh KK. Sonographically guided 14-gauge core needle biopsy of breast masses: a review of 2,420 cases with long-term follow-up. AJR Am J Roentgenol 2008;190:202–207.
crossref pmid
6. Liberman L, Feng TL, Dershaw DD, Morris EA, Abramson AF. US-guided core breast biopsy: use and cost-effectiveness. Radiology 1998;208:717–723.
crossref pmid
7. Philpotts LE, Hooley RJ, Lee CH. Comparison of automated versus vacuum-assisted biopsy methods for sonographically guided core biopsy of the breast. AJR Am J Roentgenol 2003;180:347–351.
crossref pmid
8. Youk JH, Kim EK, Kim MJ, Lee JY, Oh KK. Missed breast cancers at US-guided core needle biopsy: how to reduce them. Radiographics 2007;27:79–94.
crossref pmid
9. Perrot N, Jalaguier-Coudray A, Frey I, Thomassin-Naggara I, Chopier J. US-guided core needle biopsy: false-negatives: how to reduce them? Eur J Radiol 2013;82:424–426.
crossref pmid
10. Youk JH, Kim EK, Kim MJ, Kwak JY, Son EJ. Analysis of false-negative results after US-guided 14-gauge core needle breast biopsy. Eur Radiol 2010;20:782–789.
crossref pmid pdf
11. Fajardo LL, Pisano ED, Caudry DJ, Gatsonis CA, Berg WA, Connolly J, et al. Stereotactic and sonographic large-core biopsy of nonpalpable breast lesions: results of the Radiologic Diagnostic Oncology Group V study. Acad Radiol 2004;11:293–308.
crossref pmid
12. Zhang C, Lewis DR, Nasute P, Hayes M, Warren LJ, Gordon PB. The negative predictive value of ultrasound-guided 14-gauge core needle biopsy of breast masses: a validation study of 339 cases. Cancer Imaging 2012;12:488–496.
crossref pmid pmc
13. Crystal P, Koretz M, Shcharynsky S, Makarov V, Strano S. Accuracy of sonographically guided 14-gauge core-needle biopsy: results of 715 consecutive breast biopsies with at least two-year follow-up of benign lesions. J Clin Ultrasound 2005;33:47–52.
crossref pmid
14. Smith DN, Rosenfield Darling ML, Meyer JE, Denison CM, Rose DI, Lester S, et al. The utility of ultrasonographically guided large-core needle biopsy: results from 500 consecutive breast biopsies. J Ultrasound Med 2001;20:43–49.
crossref pmid
15. Liberman L, Drotman M, Morris EA, LaTrenta LR, Abramson AF, Zakowski MF, et al. Imaging-histologic discordance at percutaneous breast biopsy. Cancer 2000;89:2538–2546.
crossref pmid
16. Parikh J, Tickman R. Image-guided tissue sampling: where radiology meets pathology. Breast J 2005;11:403–409.
crossref pmid
17. Berg WA. Image-guided breast biopsy and management of high-risk lesions. Radiol Clin North Am 2004;42:935–946.
crossref pmid
18. Schoonjans JM, Brem RF. Fourteen-gauge ultrasonographically guided large-core needle biopsy of breast masses. J Ultrasound Med 2001;20:967–972.
crossref pmid
19. Kim MJ, Kim EK, Park SY, Jung HK, Park BW, Kim H, et al. Imaging-histologic discordance at sonographically guided percutaneous biopsy of breast lesions. Eur J Radiol 2008;65:163–169.
crossref pmid
20. Soyder A, Taskin F, Ozbas S. Imaging-histological discordance after sonographically guided percutaneous breast core biopsy. Breast Care (Basel) 2015;10:33–37.
crossref pmid pmc
21. Son EJ, Kim EK, Youk JH, Kim MJ, Kwak JY, Choi SH. Imaging-histologic discordance after sonographically guided percutaneous breast biopsy: a prospective observational study. Ultrasound Med Biol 2011;37:1771–1778.
crossref pmid
22. Jaffer S, Nagi C, Bleiweiss IJ. Excision is indicated for intraductal papilloma of the breast diagnosed on core needle biopsy. Cancer 2009;115:2837–2843.
crossref pmid
23. Cheng TY, Chen CM, Lee MY, Lin KJ, Hung CF, Yang PS, et al. Risk factors associated with conversion from nonmalignant to malignant diagnosis after surgical excision of breast papillary lesions. Ann Surg Oncol 2009;16:3375–3379.
crossref pmid pdf
24. Mercado CL, Hamele-Bena D, Oken SM, Singer CI, Cangiarella J. Papillary lesions of the breast at percutaneous core-needle biopsy. Radiology 2006;238:801–808.
crossref pmid
25. Sydnor MK, Wilson JD, Hijaz TA, Massey HD, Shaw de Paredes ES. Underestimation of the presence of breast carcinoma in papillary lesions initially diagnosed at core-needle biopsy. Radiology 2007;242:58–62.
crossref pmid
26. Pareja F, Corben AD, Brennan SB, Murray MP, Bowser ZL, Jakate K, et al. Breast intraductal papillomas without atypia in radiologic-pathologic concordant core-needle biopsies: rate of upgrade to carcinoma at excision. Cancer 2016;122:2819–2827.
crossref pmid pmc
27. Ueng SH, Mezzetti T, Tavassoli FA. Papillary neoplasms of the breast: a review. Arch Pathol Lab Med 2009;133:893–907.
crossref pmid pdf
28. Philpotts LE. Percutaneous breast biopsy: emerging techniques and continuing controversies. Semin Roentgenol 2007;42:218–227.
crossref pmid
29. Swapp RE, Glazebrook KN, Jones KN, Brandts HM, Reynolds C, Visscher DW, et al. Management of benign intraductal solitary papilloma diagnosed on core needle biopsy. Ann Surg Oncol 2013;20:1900–1905.
crossref pmid pdf
30. Goodman KA, Birdwell RL, Ikeda DM. Compliance with recommended follow-up after percutaneous breast core biopsy. AJR Am J Roentgenol 1998;170:89–92.
crossref pmid
31. Pal S, Ikeda DM, Birdwell RL. Compliance with recommended follow-up after fine-needle aspiration biopsy of nonpalpable breast lesions: a retrospective study. Radiology 1996;201:71–74.
crossref pmid
32. Kim H, Youk JH, Kim JA, Gweon HM, Jung WH, Son EJ. US-guided 14G core needle biopsy: comparison between underestimated and correctly diagnosed breast cancers. Asian Pac J Cancer Prev 2014;15:3179–3183.
crossref pmid pdf
33. Jang M, Cho N, Moon WK, Park JS, Seong MH, Park IA. Underestimation of atypical ductal hyperplasia at sonographically guided core biopsy of the breast. AJR Am J Roentgenol 2008;191:1347–1351.
crossref pmid
34. Suh YJ, Kim MJ, Kim EK, Moon HJ, Kwak JY, Koo HR, et al. Comparison of the underestimation rate in cases with ductal carcinoma in situ at ultrasound-guided core biopsy: 14-gauge automated core-needle biopsy vs 8- or 11-gauge vacuum-assisted biopsy. Br J Radiol 2012;85:e349–e356.
crossref pmid pmc
35. Lee KE, Kim HH, Shin HJ, Cha JH. Stereotactic biopsy of the breast using a decubitus table: comparison of histologic underestimation rates between 11- and 8-gauge vacuum-assisted breast biopsy. Springerplus 2013;2:551.
crossref pmid pmc

Ductal carcinoma in situ in a 31-year-old woman.

A, B. Transverse (A) and longitudinal (B) ultrasonography shows an oval microlobulated mass (arrows) categorized as BI-RADS category 4a. The result of ultrasound-guided core needle biopsy was atypical ductal hyperplasia, which was considered to be concordant. Surgical excision was recommended due to the high-risk pathology, and ductal carcinoma in situ was confirmed by excision. BI-RADS, Breast Imaging-Reporting and Data System.
usg-17028-f1.gif
Fig. 1.

Invasive ductal carcinoma in a 51-year-old woman.

A, B. Transverse (A) and longitudinal (B) ultrasonography shows a microlobulated hypoechoic mass (arrows) categorized as BI-RADS category 4b. The result of ultrasound-guided core needle biopsy was fibrocystic change, which was considered to be discordant. Vacuum-assisted biopsy was recommended immediately and invasive ductal carcinoma was confirmed by vacuum-assisted biopsy.
usg-17028-f2.gif
Fig. 2.

Invasive lobular carcinoma in a 75-year-old woman.

A, B. Ultrasonography shows a solid and cystic mass (arrows) (A) categorized as BI-RADS category 4a. The result of ultrasound-guided core needle biopsy was focal fibrosis. After 17 months, the mass increased in size from 24 to 50 mm (arrows) (B). Surgical excision was performed and invasive lobular carcinoma was confirmed.
usg-17028-f3.gif
Fig. 3.
Table 1.
Distribution of the size and BI-RADS categories of lesions assessed using US-guided 14-gauge core needle biopsy
Size (mm) BI-RADS category
Total
1 2 3 4a 4b 4c 5
≤10 0 17 (0.4) 621 (14.1) 3,157 (71.6) 230 (5.2) 215 (4.9) 168 (3.8) 4,408
10 to ≤20 2 (0.1) 6 (0.2) 415 (14.2) 1,321 (45.3) 213 (7.3) 346 (11.9) 613 (21.0) 2,916
20 to ≤30 0 4 (0.4) 120 (11.5) 285 (27.3) 67 (6.4) 135 (12.9) 433 (41.5) 1,044
30 to ≤40 1 (0.3) 4 (1.0) 54 (13.5) 84 (21.1) 32 (8.0) 36 (9.0) 188 (47.1) 399
>40 0 4 (1.3) 38 (12.6) 53 (17.6) 18 (6.0) 30 (10.0) 158 (52.5) 301
Total 3 (0.1) 35 (0.4) 1,248 (13.7) 4,900 (54.0) 560 (6.2) 762 (8.4) 1,560 (17.2) 9,068

Values are presented as number (%).

BI-RADS, Breast Imaging-Reporting and Data System; US, ultrasonography.

Table 2.
Pathological results of benign lesions on US-guided 14-gauge core needle biopsy correlated with the standard diagnostic reference
Core needle biopsy Standard diagnostic reference
Total
Benign DCIS Invasive
Benign 5,758 (98.9) 41 (0.7) 22 (0.4) 5,821
 Fibrocystic change 1,674 (99.2) 8 (0.5) 5 (0.3) 1,687
 Fibroadenoma 887 (99.8) 1 (0.1) 1 (0.1) 889
 Fibroadenomatous hyperplasia 747 (99.7) 0 2 (0.3) 749
 Papilloma 705 (96.8) 17 (2.4) 6 (0.8) 728
 Fibrosis 639 (99.1) 4 (0.6) 2 (0.3) 645
 Adenosis 350 (98.6) 5 (1.4) 0 355
 Ductal epithelial hyperplasia 162 (97.0) 3 (1.8) 2 (1.2) 167
 Duct ectasia 158 (100) 0 0 158
 Inflammation 77 (100) 0 0 77
 Fat necrosis 40 (97.6) 1 (2.4) 0 41
 Galactocele 25 (100) 0 0 25
 Foreign body reaction 20 (100) 0 0 20
 Other benign 274 (97.9) 2 (0.7) 4 (1.4) 280

Values are presented as number (%).

US, ultrasonography; DCIS, ductal carcinoma in situ.

Table 3.
Pathological results of high-risk and malignant lesions on US-guided 14-gauge core needle biopsy correlated with the standard diagnostic reference
Core needle biopsy Standard diagnostic reference
Total
Benign DCIS Invasive
High-risk 243 (75.5) 41 (12.7) 38 (11.8) 322
 Atypical ductal hyperplasia 62 (48.8) 40 (31.5) 25 (19.7) 127
 Possible phyllodes tumor 149 (91.4) 1 (0.6) 13 (8.0) 163
 Radial scar, lobular neoplasia 32 (100) 0 0 32
Malignant 0 234 (8.0) 2,691 (92.0) 2,925
 DCIS 0 219 (66.4) 111 (33.6) 330
 Invasive cancer 0 15 (0.6) 2,580 (99.4) 2,595

Values are presented as number (%).

US, ultrasonography; DCIS, ductal carcinoma in situ.

Table 4.
Delayed false-negative diagnoses after US-guided 14-gauge core needle biopsy
Patient No. BI-RADS category Core needle biopsy result Final diagnosis Interval between initial core needle biopsy and excision (mo)
1a) 4a Fibrocystic change Malignant phyllodes tumor 17
2a) 4a Intraductal papilloma DCIS 11
3 4a Epidermal cyst Metaplastic carcinoma 9
4 4b Fibroadenomatous hyperplasia Malignant phyllodes tumor 12
5 4a Stromal fibrosis Papillary carcinoma 9
6a) 4b Fibroadenoma Low grade adenosquamous carcinoma 5
7 4a Fibroadenomatous hyperplasia Invasive ductal carcinoma 12
8a) 4a Focal fibrosis Invasive lobular carcinoma 17
9 3 Almost fatty tissue DCIS 7
10a) 4a Intraductal papilloma Intraductal papillary carcinoma 17

US, ultrasonography; BI-RADS, Breast Imaging-Reporting and Data System; DCIS, ductal carcinoma in situ.

a) The radiologist recommended surgical excision immediately after the initial core needle biopsy, but the patient refused excision, resulting in a delayed false-negative diagnosis.

TOOLS
METRICS
16
Web of Science
18
Crossref
18
Scopus
14,429
View
360
Download
Editorial Office
A-304 Mapo Trapalace, 53 Mapo-daero, Mapo-gu, Seoul 04158, Korea
TEL : +82-2-763-5627   FAX : +82-2-763-6909   E-mail : office@ultrasound.or.kr
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © Korean Society of Ultrasound in Medicine.                 Developed in M2PI
Zoom in Close layer