Journal of Korean Society of Ultrasound in Medicine 2009;28(4): 281-284.
Concurrent Occurrence of Type II and Type III Endoleak of Abdominal Aortic Aneurysm Stent Graft: A Case Report.
Hyoung Su Kim, Seong Sook Hong, Jung Hoon Kim, Yong Jae Kim, Dong Erk Goo, Kui Hyang Kwon, Deuk Lin Choi
Department of Radiology, Soonchunhyang University Hospital, Korea. hongses@hosp.sch.ac.kr
  Published online: December 1, 2009.
ABSTRACT
Endoleak is an important complication following stent grafts for abdominal aortic aneurysms. Here we describe ultrasonography findings in an 86-year-old man including doppler ultrasonography and CT scan in an unusual and interesting case of the concurrent occurrence of a type II endoleak that originated from the left accessory renal artery and a type III endoleak due to shaft fracture of the stent.
Keywords: Stents; Endoluminal repair; Aortic aneurysm, Abdominal; Ultrasonography, Doppler
TOOLS