Sonazoid-enhanced ultrasonography: comparison with CT/MRI Liver Imaging Reporting and Data System in patients with suspected hepatocellular carcinoma
Article information
Abstract
Purpose
The aim of this study was to evaluate the association of contrast-enhanced ultrasound (CEUS) features using Sonazoid for liver nodules with Liver Imaging Reporting and Data System (LI-RADS) categories and to identify the usefulness of Kupffer-phase images.
Methods
This retrospective study was conducted in 203 patients at high risk of hepatocellular carcinoma (HCC) who underwent CEUS with Sonazoid from 2013 to 2016. Nodule enhancement in the arterial, portal venous, late, and Kupffer phases; CEUS LI-RADS major features; and Kupffer-phase defects were evaluated. According to the computed tomography/magnetic resonance imaging (CT/MRI) LI-RADS v2018, all nodules were assigned an LR category (n=4/33/99/67 for LR-M/3/4/5) and comparisons across LR categories were made. We defined modified CEUS LI-RADS as using Kupffer-phase defects as an alternative to late and mild washout in CEUS LI-RADS and compared the diagnostic performance for HCC.
Results
On CEUS of 203 nodules, 89.6% of CT/MRI LR-5 and 85.9% of LR-4 nodules showed hyperenhancement in the arterial phase, while 57.6% of LR-3 nodules showed hyperenhancement. Among the CT/MRI LR-5 nodules that showed arterial phase hyperenhancement or isoenhancement, 59.7% showed hypoenhancing changes from the portal venous phase, 23.9% from the late phase, and 13.4% additionally in the Kupffer phase. The modified CEUS LI-RADS showed higher sensitivity than CEUS LI-RADS (83.2% vs. 74.2%, P=0.008) without compromising specificity (63.6% vs. 69.7%, P=0.500).
Conclusion
The Kupffer phase best shows hypoenhancing changes in LR-5 lesions and is expected to improve the sensitivity for HCC in high-risk patients.
Introduction
Sonazoid (GE Healthcare, Oslo, Norway), is a second-generation ultrasound contrast agent approved in Japan, Denmark, Norway, and South Korea for use in contrast-enhanced ultrasonography (CEUS) of focal liver lesions [1]. Sonazoid consists of microbubbles of perfluorobutane gas with phospholipid monolayer shells. CEUS using Sonazoid enables imaging of the vascular phase and the post-vascular Kupffer phase (KP) [2]. Hepatic enhancement in the KP may be due to the phagocytosis of microbubbles by Kupffer cells (liver-specific macrophages), adherence of microbubbles to the liver sinusoids and tumor vascular spaces, or recirculation of microbubbles [3-5]. The American College of Radiology released the 2017 version of the CEUS Liver Imaging Reporting and Data System (LI-RADS) for focal liver lesion assessment using only pure blood-pool agents [1]. The current version of the LI-RADS does not address the use of combined blood-pool and Kupffer cell agents such as Sonazoid, although this issue is scheduled to be included in the next revision.
The Kupffer cell count reflects the progression of hepatocarcinogenesis from dysplastic nodule (DN) to overt hepatocellular carcinoma (HCC) [6,7]. It plays an important role in both the diagnosis of HCC and the differentiation of well-differentiated early HCC and DNs [8]. Active research has been recently conducted using Sonazoid-enhanced ultrasonography (US) to characterize focal liver tumors [9-11], revealing correlations between tumor differentiation and CEUS findings [6,12,13]. Sonazoid-enhanced US has the potential to assist in the evaluation of the post-treatment response [14,15] and to serve as a guide for treatment approach [16] or act as a surveillance test for HCC [17]. Nevertheless, the imaging features at each phase of Sonazoid-enhanced US for liver nodules suspected of HCC have not been well studied. Previous research has evaluated CEUS features using Sonazoid for HCC compared with computed tomography (CT) features; however, only the early vascular phase and KP were assessed [18]. Moreover, few studies have been published on CEUS features using Sonazoid for each CT/magnetic resonance imaging (MRI) LI-RADS category.
This study aimed to evaluate the associations of CEUS features using Sonazoid for liver nodules, including the major features of CEUS LI-RADS, with CT/MRI LI-RADS categories and to determine the usefulness of KP images in the diagnosis of HCC.
Materials and Methods
Compliance with Ethical Standards
This retrospective study received Institutional Review Board approval at Samsung Medical Center in Korea (SMC 2019-07-147) and the requirement for informed consent was waived.
Study Population
Between January 2013 and December 2016, 334 patients underwent CEUS using Sonazoid at our institution as a second round of imaging after an inconclusive diagnosis, for pre-treatment assessment before locoregional therapy, or for characterization of a focal liver lesion found by conventional US. Among them, 258 patients were enrolled according to the following inclusion criteria: (1) patients at high risk of HCC, and (2) patients who had available liver CT/MRI information within 3 months of the CEUS exam. Fifty-five patients were excluded due to (1) a relapsed lesion at the site of the previously treated HCC (local tumor progression), or (2) a strongly hyperechoic nodule in-whole on baseline US. Despite a contrast-specific subtraction technique known as pulse inversion harmonic imaging, there could be limitations in the assessment of contrast enhancement and washout in Sonazoid-enhanced US at a low mechanical index for hyperechoic nodules on background grayscale US [19-21]. Partly hyperechoic nodules, the non-hyperechoic portions of which could be analyzed, were included. Ultimately, 203 nodules in 203 patients were included in this study (Fig. 1).
CEUS Examinations
Sonazoid-enhanced US examinations were conducted using LOGIQ E9 (GE Healthcare, Milwaukee, WI, USA) with a 3-5 MHz curved array transducer immediately after grayscale US; 16 μg of perfluorobutane in one vial of Sonazoid was dissolved in 2 mL of water. This solution was intravenously administrated into the antecubital vein as a bolus at a dose of 0.015 mL/kg body weight, followed by a 10-mL saline flush. If the lesion was observed with poor conspicuity on grayscale or if the examiner requested it, the imaging fusion technique of CT/MRI with US was used.
The imaging protocol is summarized in Fig. 2 [21]. Grayscale (or CT/MRI fusion) and contrast-mode images were viewed on dual-screen displays and the scanner timer was used to record the time from contrast injection for all images. The timer was started after the end of contrast injection/start of saline flush. The vascular phase images were acquired during the arterial phase (AP; 10-40 seconds after contrast injection), the portal venous phase (PVP; 60 seconds after contrast injection), and the late phase (LP; 3 minutes after contrast injection). Continuous imaging, as a cine loop, was acquired during the peak of AP enhancement with the option to continue the cine loop before and after the peak, especially if tumor washout within <60 seconds was found. Intermittent imaging, comprising a series of brief image acquisitions (each lasting a few seconds and spaced apart without imaging in between), was acquired every 60 seconds. Approximately 10 minutes after contrast injection, KP images were obtained for several seconds. The scanning parameters are detailed in Supplementary Table 1.
CEUS Imaging Assessment
Two abdominal radiologists (J.A.H. and W.K.J. with 9 and 20 years of experience in abdominal imaging, respectively) independently reviewed the recorded CEUS video clips and static images. Discordances were resolved by consensus through discussions with a third radiologist (H.K.L. with 35 years of experience in abdominal imaging). The reviewers were blinded to the CT/MRI LR categories and histological diagnoses of each case.
The following imaging features were evaluated: (1) nodule echogenicity and size (cm) on grayscale; (2) nodule enhancement in the AP, PVP, LP, and KP (hyperenhancement, isoenhancement, or hypoenhancement compared to the liver in each phase); (3) pattern of wash-in (i.e., in-whole or in-part, rim, stellate vessels, or peripheral globular) in the AP if applicable; (4) if and when (i.e., within 60 seconds after contrast injection, during the PVP, LP, or KP) washout occurred (a temporal reduction in enhancement of a nodule in-whole or in-part relative to the liver after peak AP enhancement [1]); (5) major features according to CEUS LI-RADS v2017 including arterial phase hyperenhancement (APHE; a lesion becoming hyperenhancing in-whole or in-part compared to the liver in the AP that is neither rim-like nor peripheral globular) and late and mild washout (a lesion that becomes hypoenhancing compared to the liver in the PVP and LP, occurring >60 seconds from contrast injection, and without marked hypoenhancement or a punched-out appearance within 2 minutes after contrast injection) [22]; (6) KP defect (a lesion that is hypoenhancing compared to the liver in the KP [Fig. 3]); (7) ancillary features according to CEUS LI-RADS v2017 including the nodule-in-nodule sign (smaller inner nodules that differ from the larger outer nodules) and mosaic architecture (presence of randomly distributed internal nodules or compartments) [22]; (8) LR-M criteria according to CEUS LI-RADS v2017 including rim APHE (most pronounced AP enhancement in the periphery of the observation), early washout (within 60 seconds from contrast injection), or marked washout (observation appears black or punched out within 2 minutes after contrast injection) [22]. If two or more lesions were present in a single patient, a histologically confirmed lesion or the largest lesion was selected as the target lesion.
According to the CEUS LI-RADS v2017, all of the nodules were assigned to an LR category based on APHE, the nodule size, and late and mild washout. We defined a modified CEUS LI-RADS using the criterion of a KP defect as an alternative to late and mild washout and assigned LR categories according to the modified CEUS LI-RADS. When a nodule demonstrated nodule-in-nodule or mosaic architecture, the LR category was upgraded by one category up to LR-4 in both CEUS LI-RADS and the modified CEUS LI-RADS [23].
CT/MRI Imaging Assessment
A radiologist (J.H.M. with 11 years of experience in abdominal imaging) who was blinded to the CEUS findings analyzed the CT or MRI images of all 203 nodules, and assigned them to LI-RADS category according to CT/MRI LI-RADS v2018 [24]. The ancillary features and tie-breaking rules were applied. For patients with gadoxetic acid-enhanced MRI, signal intensity of the nodule in the hepatobiliary phase (HBP) was also assessed. To use as a reference standard for evaluating the diagnostic performance of CEUS for HCC, subjects were allocated into HCC and non-HCC groups based on histology, whenever available, or a CT/MRI imaging diagnosis of HCC according to the Korean Liver Cancer Association-National Cancer Center (KLCA-NCC) Korea Practice Guidelines [25]. Since the American Association for the Study of Liver Diseases and European Association for the Study of the Liver, as well as the KLCA-NCC, do not allow the imaging diagnosis of sub-centimeter-sized HCCs, an imaging diagnosis of HCC was only conducted for lesions of 1 cm or more.
Statistical Analysis
Continuous variables were reported as mean±standard deviation and range. Descriptive data were reported as numbers and percentages. Comparisons across groups were made using the chi-square test or Fisher exact test. For hepatic nodules ≥1 cm, the diagnostic performance of CEUS and modified CEUS LI-RADS was evaluated using the HCC group as the reference standard and compared using the McNemar test or Delong’s method. The analysis was performed using SPSS version 25 (IBM Corp., Armonk, NY, USA). A P-value <0.05 was considered to indicate statistical significance.
Results
Baseline Characteristics of the Study Population
A total of 203 patients (mean age, 61.3±9.5 years; age range, 32 to 83 years: 159 men [mean age, 60.6±9.0 years; age range, 34 to 79 years]: 44 women [mean age, 63.2±10.9 years; age range, 32 to 83 years]) were included. The baseline characteristics of the patients and nodules are summarized in Table 1. On grayscale US images, 141 nodules (69.5%) were hypoechoic and 62 nodules (30.5%) were isoechoic. The mean nodule size on grayscale US was 1.5±0.7 cm (range, 0.7 to 5.0 cm). All nodules were assigned to LR categories according to CT/MRI LI-RADS v2018 as follows: four nodules (2.0%) as LR-M, 33 nodules (16.3%) as LR-3, 99 nodules (48.8%) as LR-4, and 67 nodules (33.0%) as LR-5. Thirty-one nodules had histological diagnoses and among these, 23 nodules (74.2%) were HCCs.
Sonazoid-Enhanced US Features of Hepatic Nodules by CT/MRI LI-RADS Category
Sonazoid-enhanced US features of 203 hepatic nodules by CT/MRI LI-RADS category are shown in Table 2. In the AP, most CT/MRI LR-5 (89.6%) and LR-4 (85.9%) nodules showed hyperenhancement, while only 57.6% of LR-3 nodules showed hyperenhancement. The proportion of hypoenhancing nodules in all LR categories was higher in the LP than in the PVP. In the KP, 98.5% of LR-5 nodules and 92.9% of LR-4 nodules showed hypoenhancement, while only 75.5% of LR-3 nodules showed hypoenhancement.
Among the CT/MRI LR-5 nodules, 88.1% showed in-whole or in-part enhancement. Among CT/MRI LR-5 nodules that showed hyperenhancement or isoenhancement in the AP of CEUS, 59.7% showed a hypoenhancing change from the PVP, 23.9% from the LP, and 13.4% additionally in the KP (Fig. 4). Eight (24.2%) of the LR-3 nodules, seven (7.1%) of the LR-4 nodules, and one (1.5%) LR-5 nodule did not show washout until the KP.
Two of the four CT/MRI LR-M nodules showed rim APHE. One of the two nodules showed early and marked washout and was considered to be recurrent HCC in a patient who had undergone resection for scirrhous HCC. The other nodule showed late and mild washout and was proven to be sclerosing hemangioma via biopsy. None of the CT/MRI LR-3, LR-4, and LR-5 nodules satisfied the CEUS LR-M criteria.
Comparison of Sonazoid-Enhanced US Features of CT/MRI LR-3, LR-4, and LR-5 Nodules
When applying the CEUS LI-RADS major features for 199 hepatic nodules in CT/MRI LR-3, LR-4, and LR-5, APHE and late and mild washout showed significant differences across CT/MRI LI-RADS categories (P<0.001) (Table 3). APHE and late and mild washout were less frequent in CT/MRI LR-3 nodules than in LR-4 or LR-5 nodules. KP defects also showed significant differences across CT/MRI LI-RADS categories (P<0.001), and LR-3 nodules had the lowest frequency. KP defects were more frequent than late and mild washout in each CT/MRI LI-RADS category.
Comparison of the Diagnostic Performance of CEUS and Modified CEUS LI-RADS
For 122 hepatic nodules measuring 1 cm or more, the diagnostic performance of CEUS and modified CEUS LI-RADS was evaluated (Tables 4, 5). The modified CEUS LI-RADS using KP defects showed higher sensitivity than CEUS LI-RADS (83.2% vs. 74.2%, P=0.008). Although the specificity of the modified CEUS LI-RADS was lower than that of CEUS LI-RADS, the difference was not statistically significant (63.6% vs. 69.7%, P=0.500). There were no significant differences in accuracy and area under the curve (P>0.05).
Comparison of Nodule Enhancement on MRI HBP and CEUS KP Images
Table 6 shows a comparison of nodule enhancement on HBP and KP images for CT/MRI LR-3, LR-4, and LR-5 nodules in 193 patients with gadoxetic acid-enhanced MRI. Among a total of 184 hypointense nodules in the HBP, 12 nodules (6.5%) showed isoenhancement in the KP. In the comparison by each CT/MRI LR category, there was no significant difference in nodule enhancement in the HBP and KP. The proportion of nodules that appeared hypointense in the HBP but without KP defects decreased to 19.2%, 6.3%, and 1.6% as the CT/MRI LR category increased to LR-3, LR-4, and LR-5, respectively.
Sonazoid-Enhanced US Features of Histologically Diagnosed Hepatic Nodules
The frequency of HCC among histologically proven hepatic nodules was 42.9% in LR-3, 87.5% in LR-4, 85.7% in LR-5, and 50% in LR-M of the CT/MRI LR categories (Supplementary Table 2). According to the CEUS/modified CEUS LI-RADS categories, the frequency of HCC was 50% in LR-3, 66.7% in LR-4, 85.7% in LR-5, and none in LR-M—the results of nodule assignments according to CEUS LI-RADS and the modified CEUS LI-RADS were the same.
Except for nodule enhancement on the LP image, there was no significant difference in Sonazoid-enhancement US features between the HCC and non-HCC lesions (Supplementary Table 3). A unique nodule that displayed stellate vessels in the AP and subtle hypoenhancement in the PVP, LP, and KP was diagnosed as a focal nodular hyperplasia-like nodule through US-guided biopsy. However, surgical resection was performed 9 months later due to an increase in size, and the final diagnosis was HCC (Fig. 5).
In the comparison of diagnostic performance for 31 histologically proven lesions, CEUS and the modified CEUS LI-RADS showed higher sensitivity, accuracy, and area under the curve than CT/MRI LI-RADS, but without statistical significance (Supplementary Table 4). Among the eight histologically proven HCCs diagnosed as HCC in CEUS LI-RADS but not in CT/MRI LI-RADS, three had no APHE and the other three had no washout on MRI. The remaining two lesions were smaller than 1 cm on MRI, but measured more than 1 cm on US.
Discussion
In the present study, 83.6% of CT/MRI LI-RADS LR-5 nodules showing hyperenhancement or isoenhancement in the AP showed washout in the PVP or LP on CEUS. An additional 13.4% of CT/MRI LR-5 nodules yielded consistent results on CEUS and MRI when the boundary of washout was expanded to the KP. More nodules in the LR-3 category were isoenhancing until the KP than those in the LR-4 or LR-5 of CT/MRI LR categories. In the CT/MRI LR-3, LR-4, and LR-5 nodules, KP defects were more frequently seen than late and mild washout. Modified CEUS LI-RADS using KP defects had higher sensitivity for HCC diagnosis than CEUS LI-RADS without significant inferiority in specificity.
Washout might be an important feature used to distinguish malignancy from benignity [26]. A lesion showing sustained enhancement that is equal to or greater than that of the liver in the PVP of CEUS was found to suggest benignity (92% sensitivity and 93% specificity) [27]. According to previous studies using KP imaging, however, 10.0%-33.3% of HCCs showed washout only in the KP and not in the late vascular phase [7,28,29]. In this study, the modified CEUS LI-RADS using KP defects instead of late and mild washout showed a higher sensitivity for HCC diagnosis than CEUS LI-RADS without significantly compromising the specificity. The application of KP images could be reasonably expected to improve the sensitivity of HCC diagnosis.
In this study, 6.5% of CT/MRI LR-3, LR-4, and LR-5 nodules showed hypointensity in the HBP but isoenhancement in the KP. Ohama et al. [6] reported that uptake of Sonazoid started to decrease later than that of Gd-EOB-DTPA in stepwise hepatocarcinogenesis, and that hypoenhancement in the KP suggested progressive HCC. In this study, the proportion of nodules that appeared hypointense in the HBP but without a KP defect decreased as the CT/MRI LR category rose. It is difficult to distinguish between DN and early HCC for an isoenhancing nodule in the KP, because Kupffer cells can remain inside both DN and early HCC. Given that all DNs were isoenhancing in the KP compared with 42.1%-75.0% of well-differentiated HCCs [6,7,10,13,29], the possibility of DN can be excluded for hypoenhancing nodules in the KP.
Although this study did not compare a pure blood-pool agent and Sonazoid directly, the CEUS results from the vascular phase using Sonazoid seem to be comparable with those of prior studies using pure blood-pool agents. According to previous reports, washout was observed in 40.0%-90.1% of HCC in CEUS using pure blood-pool agents [30-37], and 75.0%-97.2% of HCC in Sonazoid-enhanced US [10,28]. Few studies have investigated whether the hepatic enhancement due to Kupffer cell uptake of microbubbles in the late vascular phase emphasizes washout, and whether there is a difference in washout expression between pure blood-pool agents and Sonazoid. The possibility of pseudo-washout is likely to appear in the KP as well. Therefore, an intra-individual comparison study using these agents would be the logical next step.
This study has several limitations. Firstly, given its retrospective nature, it was subject to selection bias. In many patients, CEUS was performed for pre-treatment assessment before locoregional therapy. The exclusion of strongly hyperechoic nodules in-whole on baseline US could have also caused bias, but it was inevitable considering the issue of pseudoenhancement and false masking of washout. In severe fatty liver, a nodule could also show false washout [19], but there was no such case in this study. A second limitation is that only some lesions had histological diagnoses. Among the histologically proven lesions in this study, HCC was found in 42.9% of LR-3, 87.5% of LR-4, 85.7% of LR-5, and 50% in LR-M nodules in the CT/MRI LR categories. To overcome this point, we used the KLCA-NCC 2018 guideline for the imaging diagnosis of HCC as a reference standard to assess the diagnostic performance of CEUS LI-RADS and modified CEUS LI-RADS, considering that the KLCA-NCC 2018 guideline showed higher sensitivity (79.1% vs. 68.2%, P<0.001) without compromising specificity (93.9% vs. 95.4%, P=0.314) than CT/MRI LI-RADS v2018 in a recent study [38]. Nevertheless, the specificity of CEUS LI-RADS and the modified CEUS LI-RADS in this study was 69.7% and 63.6%, respectively, which was disappointing considering that LI-RADS is aimed at high specificity. The characteristics of the KLCA-NCC guideline, which emphasizes specificity rather than sensitivity, and the relatively small size of the 122 lesions (median size, 1.4 cm) used to assess diagnostic performance in this study may have affected these results.
In conclusion, the KP best showed hypoenhancing changes in LR-5 lesions and its use is expected to improve the sensitivity for HCC in patients at high risk.
Notes
Author Contributions
Conceptualization: Jeong WK. Data acquisition: Hwang JA, Jeong WK, Lim HK. Data analysis or interpretation: Hwang JA, Jeong WK, Min JH, Kim YY, Heo NH, Lim HK. Drafting of the manuscript: Hwang JA, Jeong WK. Critical revision of the manuscript: Jeong WK, Min JH, Kim YY, Heo NH, Lim HK. Approval of the final version of the manuscript: all authors.
Woo Kyoung Jeong serves as Editor for the Ultrasonography, but have no role in the decision to publish this article. All remaining authors have declared no conflicts of interest.
Acknowledgements
This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korean government (MSIT) (No. 2019R1G1A1100144).