Controlled attenuation parameter measured using transient elastography for the noninvasive assessment of macrovesicular steatosis in potential living liver donors
Article information
Abstract
Purpose
This study aimed to determine the diagnostic performance of the controlled attenuation parameter (CAP) measured using transient elastography (TE) for assessing macrovesicular steatosis (MaS) in potential living liver donors using same-day biopsy as a reference standard.
Methods
This retrospective study included 204 living liver donor candidates who underwent TE and liver biopsy on the same day between July 2013 and June 2014. The histologic degree of MaS was determined. The area under the receiver operating characteristic curve (AUROC) was used to evaluate the performance of CAP for diagnosing MaS of >10%, and the optimal cutoff value was identified using the maximal Youden index.
Results
Based on liver biopsy, 185 subjects had MaS of ≤10% and 19 had MaS of >10%. The CAP value was significantly correlated with the percentage of MaS on liver biopsy (r=0.635, P<0.001), and the median CAP value was significantly higher in subjects with MaS of >10% than in those with MaS of ≤10% (300 dB/m vs. 209 dB/m, P<0.001). The AUROC for diagnosing MaS of >10% by CAP was 0.938 (95% confidence interval, 0.896 to 0.967), and a CAP of >259 dB/m yielded a sensitivity of 84.2% and a specificity of 92.4%.
Conclusion
The CAP measured using TE was significantly correlated with MaS and accurately detected substantial MaS in potential living liver donors. The CAP is a promising tool for the noninvasive diagnosis of MaS and may be used to screen unsuitable living liver donor candidates.
Introduction
Liver transplantation (LT) is the most effective treatment for end-stage liver disease [1]. Most LT centers in Asia predominantly perform living donor LT (LDLT) due to a shortage of deceased organ donations [2]. However, a rising incidence of nonalcoholic fatty liver disease (NAFLD) in the general population has been reflected in an increasing prevalence of living liver donors with NAFLD [3]. The degree of macrovesicular steatosis (MaS) in donated livers is known to be a critical factor determining outcomes after transplantation. MaS affects the recovery of the remnant liver in living donors as well as graft function in recipients. Therefore, the evaluation of MaS in donated livers is crucial, particularly for LDLT, during which donor safety is a primary concern. Many LDLT centers prefer to accept right liver donors with MaS of up to 10% [4-6]. According to the International Liver Transplant Society guideline on living liver donation, MaS of >10% is considered substantial [7].
Liver biopsy is considered the gold standard for assessing the degree of hepatic steatosis [8]. Although this procedure has a relatively low complication rate in healthy living donors [9], it is an invasive procedure that can lead to morbidity [10]. Therefore, noninvasive methods have been investigated for the evaluation of steatosis. Recently, the controlled attenuation parameter (CAP) measured using transient elastography (TE) has been proposed as a promising noninvasive method for the detection and quantification of hepatic steatosis [11]. The CAP measured using TE has been validated for the assessment of steatosis in patients with chronic liver disease of various etiologies [12], and meta-analyses have shown good diagnostic accuracy of CAP for identifying hepatic steatosis [13-16]. However, only a few studies have investigated the usefulness of CAP for assessing steatosis in potential living liver donors [17,18]. In addition, to the authors’ knowledge, the potential role of CAP in identifying substantial MaS in living liver donor candidates has not yet been evaluated.
Therefore, this study aimed to determine the diagnostic performance of CAP for the assessment of MaS in potential living liver donors using same-day biopsy samples as a reference standard.
Materials and Methods
Compliance with Ethical Standards
The study was approved by the institutional review board of the authors’ institution (IRB approval number: AMC 2021-0378). The requirement for written informed consent was waived due to the retrospective nature of the analysis.
Study Population
Between July 2013 and June 2014, 299 potential living liver donors underwent ultrasound (US)-guided liver biopsy as part of a routine predonation work-up. Liver biopsy was performed if candidates met the following conditions: (1) no more than 20 g of alcohol consumption per day; (2) no regular drug use including herbal medications; and (3) no serological evidence of hepatitis B, hepatitis C, or human immunodeficiency virus infection. Subjects were considered eligible for inclusion in our study if they were living liver donor candidates who had undergone TE with CAP and liver biopsy on the same day. Donor candidates who had undergone TE and liver biopsy on different days (n=70) or who had unreliable CAP measurements (n=25) were excluded (Fig. 1).
Clinical and Laboratory Data
Demographics (age and sex), anthropometric measurements (body weight and height), and laboratory data (aspartate aminotransferase [AST], alanine aminotransferase [ALT], alkaline phosphatase [ALP], γ-glutamyl transpeptidase [GGT], total cholesterol, triglycerides, high-density lipoprotein [HDL], low-density lipoprotein [LDL], and fasting glucose) were collected. Body mass index (BMI) was calculated as body weight (kg) divided by the square of height (m2).
TE and CAP Measurements
CAP measurements were obtained using TE (FibroScan 502 touch, Echosens, Paris, France) by trained technicians blinded to patients’ clinical and histologic data. All measurements were performed on the right hepatic lobe through the intercostal spaces of the donor candidates lying in the dorsal position with the right arm in abduction. The CAP was calculated as the attenuation of the ultrasonic signal at 3.5 MHz acquired by TE. The principles of CAP measurement have been previously described in detail [19]. The CAP values were expressed in dB/m, and the median of successful measurements was selected as the representative value. The success rate was calculated as the ratio of the number of successful acquisitions to the total number of measurements. As an indicator of variability, the interquartile range (IQR)-to-median ratio was calculated. In this study, CAP measurements with 10 valid shots, a success rate of at least 60%, and an IQR-to-median ratio of less than 30% were considered reliable and used for statistical analysis [20,21].
Liver Biopsy
US-guided percutaneous biopsy was performed during the living liver donor work-up on the right hepatic lobe using an 18-gauge needle (Stericut 18G coaxial, TSK Laboratory, Tochigi, Japan). Two or more biopsy specimens, each approximately 1.5 cm in length, were obtained and stained with hematoxylin and eosin. The degree of MaS, which was the percentage of hepatocytes that contained intracellular macrovesicular fat droplets, was assessed quantitatively. MaS of >10% was considered to be substantial [7].
Statistical Analysis
Continuous variables were expressed as means with standard deviations or medians with IQRs, as appropriate. Pearson correlation coefficients (r) were calculated to evaluate correlations between variables. Differences between two continuous variables were analyzed using the Mann-Whitney U test. The normality of the CAP values in the reference population with histologic MaS of ≤10% was checked using the Shapiro-Wilk test. The lower and upper limits of the reference range were estimated to be the 2.5th and 97.5th percentiles, respectively, of the distribution of CAP values in the reference population. The performance of CAP for diagnosing substantial MaS (>10%) was estimated using the area under the receiver operating characteristic curve (AUROC) with the 95% confidence interval (CI). The cutoff value for CAP was chosen to maximize the sum of the sensitivity and specificity on the Youden index. At the optimal cutoff value, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) with their 95% CIs were determined. A P-value of <0.05 was considered to indicate statistical significance. Statistical analyses were performed using SPSS version 23.0 (IBM Corp., Armonk, NY, USA) and MedCalc version 16.2.1 (MedCalc Software, Ostend, Belgium).
Results
Characteristics of the Study Subjects
A total of 204 potential living liver donors (mean age, 30.5±9.1 years; 133 male and 71 female) were included in the analysis. The characteristics of the included subjects are summarized in Table 1. Of these donor candidates, 185 (90.7%) had MaS of ≤10% and 19 (9.3%) had MaS of >10%. The median CAP value in our study subjects was 214 dB/m (IQR, 190 to 241 dB/m).
Correlations with CAP
CAP was significantly correlated with BMI (r=0.561, P<0.001), AST (r=0.302, P<0.001), ALT (r=0.448, P<0.001), GGT (r=0.231, P=0.001), total cholesterol (r=0.283, P<0.001), triglycerides (r=0.364, P<0.001), HDL (r=-0.270, P<0.001), LDL (r=0.309, P<0.001), fasting glucose (r=0.195, P=0.005), and the percentage of MaS on liver biopsy (r=0.635, P<0.001) (Fig. 2) but not with ALP (Table 2).
Distribution of CAP Based on MaS
The median CAP values for subjects with MaS of ≤10% and MaS of >10% were 209 dB/m (IQR, 188 to 233 dB/m) and 300 dB/m (IQR, 261 to 313 dB/m), respectively. CAP values were significantly higher in subjects with MaS of >10% than in those with MaS of ≤10% (P<0.001) (Fig. 3).
Reference Range for CAP in patients with MaS of ≤10%
The CAP values in the reference population with histologic MaS of ≤10% ranged from 149 to 276 dB/m and followed a Gaussian distribution (P=0.170, Shapiro-Wilk test) (Supplementary Fig. 1).
Diagnostic Performance of CAP for MaS
For diagnosing substantial MaS (>10%), the AUROC of CAP was 0.938 (95% CI, 0.896 to 0.967), and the optimal cutoff value was determined to be 259 dB/m (Fig. 4). Using this cutoff value, the sensitivity, specificity, PPV, and NPV for diagnosing substantial MaS (>10%) were 84.2% (95% CI, 60.4% to 96.6%), 92.4% (95% CI, 87.6% to 95.8%), 53.3% (95% CI, 34.3% to 71.7%), and 98.3% (95% CI, 95.0% to 99.6%), respectively (Table 3).
Discussion
This study demonstrated that the CAP obtained using TE was closely correlated with the degree of MaS in histologic analyses of biopsy samples from potential living liver donors. Our results also showed that CAP had excellent diagnostic accuracy for detecting substantial MaS, with an AUROC of 0.938. Therefore, CAP is potentially useful for identifying substantial MaS (>10%), which may hinder the success of LT.
MaS in donated livers has been reported to be associated with poor graft function, including early graft dysfunction and primary nonfunction in recipients, which can result in decreased graft survival [22]. MaS also impairs the recovery and regeneration of remnant liver in living donors. The large fat vacuoles of MaS are believed to reduce sinusoidal blood flow and disturb the hepatic microcirculation, making liver grafts more vulnerable to ischemia-reperfusion injury [23]. In addition, cellular, biochemical, and signaling processes are interrupted in hepatic steatosis, leading to mitochondrial dysfunction and endoplasmic reticulum stress, which can affect the process of liver regeneration [24]. Although the acceptable degree of MaS for living liver donation remains controversial, MaS of less than 10% has been commonly used as a threshold for LDLT to ensure recipient outcome and donor safety [4-6].
Limited studies have evaluated hepatic steatosis in potential living liver donors using the CAP measured by TE [17,18]. Hong et al. [17] evaluated the usefulness of CAP for detecting steatosis in 55 living liver donor candidates. The authors found that the AUROC of CAP for identifying total steatosis (>33%) was 0.88 with a cutoff value of 276 dB/m using US-guided liver biopsy as the reference standard [17]. In another study by Yen et al. [18], 54 living liver donors were assessed using the CAP, and the results were compared with intraoperative biopsy. In that study, the CAP had an AUROC of 0.96 for detecting total steatosis (>5%) with a cutoff value of 257 dB/m [18]. Though these studies were limited by relatively small sample sizes, their findings suggest the utility of the CAP for detecting total steatosis.
Unlike these previous studies, we focused on MaS rather than total steatosis, since MaS is known to be independently associated with graft dysfunction [25,26]. This study demonstrated the excellent diagnostic accuracy of the CAP for detecting substantial MaS (>10%) in potential living liver donors, with an AUROC of 0.938. We found that the optimal cutoff value of the CAP for identifying substantial MaS was 259 dB/m, with a sensitivity of 84.2% and a specificity of 92.4%. The CAP measured by TE has many advantages, including its noninvasive, nonionizing, quantitative, rapid, and reproducible features, suggesting that this parameter may be a promising tool for screening potential living liver donors. In living liver donor candidates, a CAP cutoff value of 259 dB/m may potentially be used to detect those with substantial MaS.
Previous studies have shown that rates of unreliable CAP measurements ranged from 28% to 57% in the population with chronic liver disease or NAFLD [27-29]. Although the rate of unreliable CAP measurements in our study was lower than in previous studies of patients with chronic liver disease or NAFLD, the rate of unreliable CAP measurements in our study (8.4%) was somewhat disappointing because living liver donor candidates are usually young and healthy. The unreliable measurement rate may be a limitation of the CAP.
This study had several limitations. First, it was a single-center, retrospective study in which selection bias was unavoidable. Second, the number of subjects with MaS of >10% was small. Third, this study was conducted in an East Asian population with a mean BMI of 22.7 kg/m2, potentially limiting its applicability to a Western population. Due to these limitations, our results need to be validated in prospective, large-scale, multi-center studies.
In conclusion, the CAP measured by TE was significantly correlated with MaS and accurately detected substantial MaS in potential living liver donors. Thus, the CAP is a promising tool for the noninvasive diagnosis of MaS and may be used to screen unsuitable living liver donor candidates.
Notes
Author Contributions
Conceptualization: Lee S, Kim KW. Data acquisition: Lee S, Kim KW, Kim SY, Seo N, Song GW, Lee SG. Data analysis or interpretation: Kim KW. Drafting of the manuscript: Lee S, Kim KW. Critical revision of the manuscript: Kim KW, Kim SY, Seo N, Song GW, Lee SG. Approval of the final version of the manuscript: all authors.
No potential conflict of interest relevant to this article was reported.
Supplementary Material
References
Article information Continued
Notes
Key point
Controlled attenuation parameter (CAP) measured using transient elastography (TE) was significantly correlated with macrovesicular steatosis (MaS). CAP accurately detected substantial MaS (>10%) in potential living liver donors. CAP is a promising tool for the noninvasive diagnosis of MaS and may be used to screen unsuitable living liver donor candidates.